Dell PowerEdge 1950 Bilgi Güncellemesi - Sayfa 6

Sunucu Dell PowerEdge 1950 için çevrimiçi göz atın veya pdf Bilgi Güncellemesi indirin. Dell PowerEdge 1950 50 sayfaları. Trusted platform module (tpm) update
Ayrıca Dell PowerEdge 1950 için: Kurulum Bilgileri (11 sayfalar), Kurulum Kılavuzu (10 sayfalar), Güncelleme (2 sayfalar)

Dell PowerEdge 1950 Bilgi Güncellemesi
Table 1-1. System Messages
Message
The FBD link to the
following DIMM failed
to train: DIMM x
FBD training error -
The following memory
branch has been disabled:
Branch x
LCD Status Messages Update
Table 1-2 lists updates to the LCD status messages that can occur and the probable cause for each
message. The LCD messages refer to events recorded in the system event log (SEL). For information on
the SEL and configuring system management settings, see your systems management software
documentation.
Table 1-2. LCD Status Messages
Code
Text
E1118
CPU Temp Interface
E122B
0.9 V Over Voltage
E122C
CPU Power Fault
NOTE:
Each diagnostic LCD message is assigned a priority. The highest priority messages will supersede
any group of messages with a lower priority.
4
Information Update
Causes
An error has occurred on the
FBD channel that contains the
specified DIMM. A fault is
indicated on the link adjacent
to the DIMM caused by a faulty
condition in either the specified
DIMM, the next DIMM in the
channel, or possibly the system
board. When this error occurs,
the other FBD branch in the
memory pair is disabled,
resulting in the second error
message.
Causes
The BMC is unable to determine
the CPU(s) temperature status.
Consequently, the BMC increases
the CPU fan speed to maximum
as a precautionary measure.
0.9 V regulator voltage has exceeded
the allowable voltage range.
A voltage regulator failure was detected
when the processor regulator(s) was
enabled.
Corrective Actions
Reseat all of the DIMMs on the
indicated FBD channel. See
"Memory" in the Hardware Owner's
Manual for information about the
FBD branches and channels. See
"Troubleshooting System Memory" in
the Hardware Owner's Manual. If the
problem persists, see "Getting Help"
in the Hardware Owner's Manual.
Corrective Actions
Turn off power to the system
and restart the system. If the
problem persists, see "Getting
Help" in the Hardware Owner's
Manual.
See "Getting Help" in the
Hardware Owner's Manual.
See "Getting Help" in the
Hardware Owner's Manual.