Dell PowerEdge C1100 Kullanım Talimatları - Sayfa 6
Sunucu Dell PowerEdge C1100 için çevrimiçi göz atın veya pdf Kullanım Talimatları indirin. Dell PowerEdge C1100 32 sayfaları. Poweredge series
Ayrıca Dell PowerEdge C1100 için: Bilgi Güncellemesi (14 sayfalar), Portföy Kılavuzu (27 sayfalar)
Logging into the Web User Interface
Enter the BMC-embedded server IP address or URL into the address bar of the web browser. The
BMC interface has a default of (DHCP\Static). Enter the system BIOS setup with <F2> to
change these settings.
When connecting to the BMC, the login screen prompts for the username and password. This
authentication with Secure Sockets Layer (SSL) protection prevents unauthorized intruders from
gaining access to the BMC web server. Once authentication is passed, you can manage the server by
privilege. At the same time, the PHP Hypertext Preprocessor (PHP) records all user information,
including user ID and privilege.
System Features
System Summary
The System Summary tab enables you to view the firmware version, hardware version, and IPv4
information. Click the System tab to view the Remote Management Controller.
Table 1-1.
BMC Information
BMC Information
Date/Time
Firmware Version
Firmware Updated
MAC Address
Table 1-2. IPv4 Information
IPv4 Information
Enabled
IP Address
Gateway
Subnet Mask
6
Using the Baseboard Management Controller
Description
Current time in the form:
Day MMM DD HH:MM:SS:HH YYYY
Dell Remote Management Controller firmware version.
Date the firmware was last flashed in the form:
Day MMM DD HH:MM:SS:HH YYYY
MAC address for the Baseboard Management Controller.
Description
Yes or No
The 32-bit address that identifies the NIC to a host. The value is in
the dot separated format, such as 143.166.154.127.
The address of a router or a switch. The value is in the dot separated
format, such as 143.166.154.1.
The Subnet Mask identifies the parts of the IP Address that are the
Extended Network Prefix and the Host Number. The value is in the
dot separated format, such as 255.255.0.0.