Dell PowerEdge C6100 Talimat Kullanımı - Sayfa 26
Sunucu Dell PowerEdge C6100 için çevrimiçi göz atın veya pdf Talimat Kullanımı indirin. Dell PowerEdge C6100 48 sayfaları. Poweredge series
Ayrıca Dell PowerEdge C6100 için: Portföy Kılavuzu (27 sayfalar)
Table 1-25. Firmware Commands (NETFUN: 08H, 09H)
Commands
Update Firmware
26
Using the Baseboard Management Controller
NetFn
CMD
Request and Response
Firmware 01H
REQUEST
Byte 1
Interface Used—Interface the image is transmitted through:
00H: System interface, e.g., KCS
01H: Networking, e.g., TFTP , FTP , or HTTP
02H: USB MSC
Byte 2
Update Type:
[7]: Force update.
0H: Normal update. An update operation occurs only when the
BMC validates the target board, target product, and version
number.
[6.0]: Reserved
Byte 3:14
Install Options:
This field is optional. If present, it contains the list of options
that control the installation procedure. The number definitions
are specific to the vendor.
RESPONSE
Byte 1 — Completion code
Byte 2 — Task ID