Dell PowerEdge M520 Manuel - Sayfa 6

Sunucu Dell PowerEdge M520 için çevrimiçi göz atın veya pdf Manuel indirin. Dell PowerEdge M520 25 sayfaları. Dell poweredge blade servers getting started guide
Ayrıca Dell PowerEdge M520 için: Bilgi Güncellemesi (38 sayfalar), Sürüm Notları (27 sayfalar), Kullanıcı Kılavuzu (23 sayfalar), Önemli Bilgiler Kılavuzu (35 sayfalar), Güncelleme Kılavuzu (32 sayfalar), Güncelleme Kılavuzu (28 sayfalar), Kullanıcı Kılavuzu (26 sayfalar), Kullanıcı Kılavuzu (22 sayfalar), Başlangıç Kılavuzu (12 sayfalar), Teknik Kılavuz (46 sayfalar), Teknik Kılavuz (45 sayfalar), Portföy Kılavuzu (27 sayfalar), Başlangıç Kılavuzu (14 sayfalar), Başlangıç Kılavuzu (12 sayfalar)

Dell PowerEdge M520 Manuel
Rev 1.00
1
Overview
This manual explains the use of the embedded software management of the 10GbE PTM. It
explains how to connect to the 10GbE PTM and to the CMC, and how to update the module and
device firmware and software.
This manual covers the following topics:
• The rest of this section provides a high-level overview of the I/O Module structure and capabili-
ties
Section 2, "Connecting to the 10GbE PTM CLI," on page 9
the 10GbE PTM and issue CLI commands
Section 3, "Command Line Interface (CLI) Reference," on page 13
Section 4, "Operating Procedures," on page 22
tions required to achieve tasks such as software update
1.1

Port Groups

The 10GbE PTM has 16 front panel ports divided into two groups: A and B. Group A consists of
ports 1 through 8, providing service to blades 1 through 8, respectively; Group B consists of ports
9 through 16, providing service to blades 9 through 16, respectively.
The supported link protocol for all internal ports is 10GBase KR
Figure 1 shows the front panel ports and their partitioning into Group A and Group B.
D
D
D
1.2

Port Link State Reflection

The 10GbE PTM reflects the link state from the uplink to the downlink. When an uplink port con-
nected to a remote peer (e.g. an Ethernet switch) is disconnected, the respective server blade will
indicate link down event. When the uplink port is connected, the respective server blade will indi-
cate link up.
1.3

Link Protocol Mismatch Condition

A port may enter a link protocol mismatch condition. When in this condition, the port links (both
uplink and downlink) will remain inactive. Mismatch condition is indicated by the port LEDs.
Additional information about the mismatch condition is available via the CLI. Link protocol mis-
match would occur under the following conditions:
6
Figure 1: Front Panel Link Speed Port Groups
10 Gb Ethernet Pass Through -k
, explains how to connect to
documents the CLI
describes the detailed sequence of opera-
Software User's Manual