Chapter 4: Disk Array Configuration
The following sections document how to configure disk arrays and filesystems on storage arrays so they can be used for
Capture and Indexing. Make sure the Sensor (server) and storage arrays are cabled correctly (see
Storage
Arrays) and powered on in the correct order (see
ensure the storage arrays can communicate with the Sensor's RAID controllers.
Clear Disk Arrays on the Storage Array
Default disk arrays on storage arrays must be cleared before filesystems can be installed on them and configured for Capture
and Indexing.
NOTE: If your Sensor System includes multiple storage arrays, you must perform the following procedure to clear the disk
arrays for each storage array, entering its unique IP address and credentials each time.
WARNING!
The following procedure clears all storage arrays connected to the server. If you have multiple storage arrays,
take care not to inadvertently clear the wrong one.
WARNING!
If you are re-configuring an existing Sensory system, run the scotus stop command to cease all processes in
Security Analytics before re-configuring the disk arrays.
To clear disk arrays on a storage array:
1. Verify the following requirements have been met, as instructed in the Security Analytics Server Quick Start Guide and
Security Analytics Storage Quick Start Guide:
The Sensor's eth0 (bond0) port is connected to the management network switch.
The storage array's Network port on Controller A is connected to the management network switch.
2. Log on to the Sensor's Linux console, or SSH to the Sensor, with the following credentials: root | 5o1Er@*
3. Enter the following command to clear all disk arrays on the storage array:
/usr/local/sbin/powervault_clear.py -i <ME4 IP address> -u <username> -p <password>
For example:
# powervault_clear.py -i 10.10.10.10 -u admin -p admin
For storage arrays with no existing array configuration, the following results are returned:
Connecting ...
Session Established
No action was required. (2020-07-30 10:25:33)
Command completed successfully. (2020-07-30 10:25:33)
All of the initiators have been deleted. (2020-07-30 10:25:33)
Command completed successfully. (2020-07-30 10:25:33)
Command completed successfully.
4. Enter the following command to reboot the storage array:
# sudo reboot
Powering On Sensor Systems on page
Security Analytics
Configuration Guide
Chapter 2, Connect the
18) before proceeding, to
Gen14 Dell Hardware
21