DH Wireless Solutions PDN Genesis S2 Saha El Kitabı - Sayfa 13

Acil Durum Telefonu DH Wireless Solutions PDN Genesis S2 için çevrimiçi göz atın veya pdf Saha El Kitabı indirin. DH Wireless Solutions PDN Genesis S2 20 sayfaları.

PDN Genesis
Field Manual
S2
Problem/
Possible
Symptom
Cause
Batteries
must be
replaced
Battery
voltage
is below
6 volts
Battery has
been deeply
discharged
Verification
Determine if battery is
accepting charge. Measure
voltage with a voltmeter. Plug
into charger and measure
again. Determine if voltage
increases within one minute.
Remove service cover.
Check LED lights on battery
charger. If LED lights
alternate red and green,
battery is not connected.
Solid red indicates charging.
Solid green indicates full
charge.
Charging time is based on
average depth of discharge.
Deeply discharged batteries
can take up to 24 hours
to recharge.
13
Possible
Corrections
If voltage has not
increased, then battery
should be tested and
replaced if necessary.
Power device with AC or
DC power cables while
battery is charging. For deep
discharge, a master jump
start may be necessary
to allow charger to begin
charging. Contact DHWS
Support for assistance.
Power device with AC or
DC power cables while
battery is charging. For deep
discharge, a master jump
start may be necessary
to allow charger to begin
charging. Contact DHWS
Support for assistance.
877.524.0430