Allied Telesis SB251-10 Yayın Notu - Sayfa 6

Yazılım Allied Telesis SB251-10 için çevrimiçi göz atın veya pdf Yayın Notu indirin. Allied Telesis SB251-10 14 sayfaları. Patch for switchblade 4000 series switches and at-9800 series switches

Allied Telesis SB251-10 Yayın Notu
6
The PORT parameter of the SET STP PORT command specifies either all
the ports in a trunk group, or none of the ports in a trunk group.
The STPFORWARD parameter has been added to the ENABLE
SWITCH and DISABLE SWITCH commands. If STPFORWARD is
enabled, and there is no enabled STP instance, then the switch will
forward all received BPDUs. If STPFORWARD is enabled, and an STP
instance is enabled, then STPFORWARD will be disabled by default and
a message will be generated.
The SHOW SWITCH command now shows the status of the BPDU
Forwarding feature.
PCR: 03401
Module: SWI
An enhancement has been made to the Test module to optimise the
reception of the loopbacked packets that are used to confirm operation of
the switch ports.
Features in SB251-06
Patch file details are listed in Table 5.
Table 5: Patch file details for Patch SB251-06.
Base Software Release File
Patch Release Date
Compressed Patch File Name
Compressed Patch File Size
Patch SB251-06 includes all issues resolved and enhancements released in
previous patches for Software Release 2.5.1, and the following enhancements:
PCR: 03340
Module: SWI, SYSR
After a power cycle, or a reboot command, the SwitchBlade would
occasionally repeatedly restart if it had two active controller cards. Also, the
Slave controller card would sometimes not take over if the Master controller
card failed.
Features in SB251-05
Patch file details are listed in Table 6.
Table 6: Patch file details for Patch SB251-05.
Base Software Release File
Patch Release Date
Compressed Patch File Name
Compressed Patch File Size
Patch Release Note
sb-251.rez
10-Apr-2003
sb251-07.paz
79684 bytes
sb-251.rez
31-Mar-2003
sb251-05.paz
71096 bytes
Patch SB251-10 for Software Release 2.5.1
Level: 1
C613-10361-00 REV J