Christ CLM1000 Standard Kullanım Kılavuzu - Sayfa 8
Ölçüm Cihazları Christ CLM1000 Standard için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Christ CLM1000 Standard 12 sayfaları. Wattmeter
Display
0.231
RESET
Amax
0.196
7(9)
Amin
43.7
RESET
Wmax
34.9
8(9)
Wmin
RESET
82,5
ON%
10:02
9(9)
ONh
2.3.3. Description of the ON%-function
Many consumers (e.g. refrigerator) not constantly need the full
achievement from the net. Therefore it is good to be known which time a
consumer really needs the full electrical power and not only works in the
standby-mode.
The function indicates how much percent of the measured time and how
many hours the consumers worked over the adjusted ON-threshold
(Standby-threshold).
The following diagram illustrates the measurement principle.
Real power
„ON%"-Time
7
Mode of operation Range
Max. Current [A]
Min. Current [A]
Max. real power
[W]
Min. real power
[W]
ON Time [%]
ON Time [h]
Start
0,000 - 16,00 A
0,000 - 16,00 A
0,0 - 4224 W
0,0 - 4224 W
0,00 - 100,0 %
00:00 - 9999:59 h
t
t
Stop
Start
Meaning
Maximum current of the
measuring.
Minimum current of the
measuring.
Maximum real power of
the measuring.
Minimum real power of
the measuring.
Percent and time over
the adjusted ON-
threshold.
(Standby-threshold)
ON-
threshold
(Standby-
thereshold
E461755