Dell POWER VAULT 130T LIBRARY 130T Güvenlik Kitapçığı - Sayfa 9
Depolama Dell POWER VAULT 130T LIBRARY 130T için çevrimiçi göz atın veya pdf Güvenlik Kitapçığı indirin. Dell POWER VAULT 130T LIBRARY 130T 10 sayfaları. Tape library
Ayrıca Dell POWER VAULT 130T LIBRARY 130T için: Kurulum Kılavuzu (13 sayfalar)
English Version of Service Manual
Safety Notices
S01
If you are replacing a FRU or CRU because of a fault symptom code (FSC), run diagnostic
tests to make sure you can duplicate the problem. After you have replaced the FRU or
CRU, run the diagnostic tests again to make sure the problem has been fixed.
Caution: Review the following steps before attempting to remove and replace
any FRUs or CRUs.
1.
Follow the safety and electrostatic discharge (ESD) precautions outlined in About this
Manual at the beginning of this document.
2.
Follow the safety precautions outlined in Rack-Mounted Library Safety and
Precautions in About this Manual.
3.
Read each procedure completely to familiarize yourself with the warnings and steps
involved with the procedure before starting.
4.
End all jobs being performed by the library and place the tape drives offline before
removing power. Removing power without placing the drives offline could result in
loss of data or damage to the cartridge tape.
Caution: Possible equipment problems: Observe these SCSI bus precautions
when disconnecting the SCSI cables from the PowerVault 130T library and tape
drives.
•
Before connecting the external SCSI cables, make sure there is no activity on the SCSI
bus. The host must be quiesced; do not connect to a hot bus.
•
All signals must be terminated at each end of the SCSI bus. Do not mix single-ended
and differential terminators.
S02
Warning: Possible physical injury! When the Tape Drive assembly is not installed
into the PowerVault 130T, DO NOT apply power.
Safety Booklet
1-3