Dell Express Fla SCSI Disk Device instead of NVMe Dell Express Flash SCSI Disk
Device.
Cause
In Windows 2012 R2, there is a new flag
STOR_FEATURE_DEVICE_NAME_NO_SUFFIX that removes the suffix in the
device friendly name. This is only seen in Windows 2012 R2 and this flag is enabled
by design of the Windows 2012 R2 in-box driver. The Dell-provided NVMe driver
uses the correct flag, but you may see the device name truncated intermittently.
Solution
This is a known issue and the message can be ignored.
Software RAID Array Created Using PCIe SSDs Is Not Detected After SLES 11
SP3 Is Rebooted
Cause
The boot.md service is not started during RAID creation. The boot.md service must
be activated for the init process to start the MD-RAID device.
Solution
Run the command # chkconfig boot.md to verify if the boot.md service is on
or off. This command should start the boot.md service. If it does not, run the
command # chkconfig boot.md on to enable it.
NVMe PCIe SSD Is Not Listed In the Operating System
Cause
Hardware is not correctly installed.
Solution
Check the following components:
•
•
•
Devices: Ensure that the NVMe PCIe SSDs are installed in an NVMe PCIe SSD
backplane.
CAUTION: NVMe PCIe SSDs must be used with NVMe PCIe SSD
backplanes. To ensure that you have the correct configuration for the
NVMe PCIe SSD, see the platform-specific Owner's Manual at dell.com/
support/manuals.
Backplane: Ensure that the cables for the NVMe PCIe SSD backplane are
connected correctly.
NOTE: The backplane connector cables are labeled as PCIe BP A, PCIe BP
B, PCIe BP C, and PCIe BP D for connecting to the backplane. The PCIe
extender adapter card cable connectors are labeled as adapter port A, B, C,
and D respectively for connecting to the card. These cables must not be
reversed.
Cables: PCIe cables are unique for the configuration. Ensure that the backplane
cable connectors are connected to the backplane and the extender card cable
connectors are connected to the extender card. See
Hardware.
Extender card: Ensure that the PCIe extender card is plugged into the correct
supported slot. See the system specific Owner's Manual at dell.com/support/
manuals.
Replacing And Configuring