Figure 10. Screw Location
2. Using a ball-head Allen driver, remove the fifteen screws. Use an
11.5-inch–long, 5/64-inch ball-head Allen driver to remove the screws
located inside the enclosure services module bays on the left and right side
of the chassis (see Figure 11).
NOTE: A magnetized 11.5-inch–long, 5/64-inch ball-head driver is included
with the SCSI backplane board in the service kit.
screw
screw
Figure 11. Screw Location in the Left Enclosure Services Module Bay
3. Separate the two chassis halves to remove the backplane board (see
Figure 12).
Figure 12. Chassis Separation
Dell PowerVault 2xxS Storage Systems SCSI Backplane Board Replacement Instructions
image shown without chassis
left-side enclosure services
module is shown
9