Dell PowerVault LTO-3-060 Kullanıcı Kılavuzu - Sayfa 24

Depolama Dell PowerVault LTO-3-060 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Dell PowerVault LTO-3-060 37 sayfaları. Powervault tape systems
Ayrıca Dell PowerVault LTO-3-060 için: Kurulum (2 sayfalar), El Kitabı (28 sayfalar)

Dell PowerVault LTO-3-060 Kullanıcı Kılavuzu
Key:
= OFF
= ON
= Flashing slowly
= Flashing rapidly
4. Double-click the Unload button to activate the service function.
5. The service function is complete when all drive status LEDs go off except for Ready, which will turn on solid. This indicates that the drive has exited service
mode.
6. To verify that the dump is in flash memory, complete the following steps.
a. Ensure there is no cartridge in the drive.
Note:
If a cartridge is loaded in the drive, the Unload button is interpreted as an unload request and the drive will ignore the second and third depressions.
The drive cannot be put into Service mode while a cartridge is loaded.
b. Press and hold the Unload button until the Ready LED begins flashing rapidly indicating Service Function 1 has been accessed. The status LEDs will be in
the following states.
LED icon
Key:
= OFF
= ON
= Flashing rapidly
c. Verify that the Fault LED is solid ON.
If the Fault LED is solid ON, then the dump is in flash memory.
n
If the Fault LED is not solid ON, repeat the Service Function 4 procedure.
n
d. Press the Unload button once per second until you exit from Service mode and the Ready light comes ON solid.
Executing Service Function 5: Erase flash
     
Service Function 1; drive dump in flash memory