Dell PowerVault MD3000i Kullanıcı Kılavuzu - Sayfa 41

Depolama Dell PowerVault MD3000i için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Dell PowerVault MD3000i 46 sayfaları. Configuration for vmware esx server software
Ayrıca Dell PowerVault MD3000i için: Ayarlama Kılavuzu (32 sayfalar), Destek Notu (22 sayfalar), Yükseltme Kılavuzu (28 sayfalar), Değiştirme Kılavuzu (4 sayfalar), Yapılandırma Kılavuzu (10 sayfalar)

Dell PowerVault MD3000i Kullanıcı Kılavuzu
Figure 30. vCenter Plug-in Log File
Additional log files are also maintained in this directory that are useful for
technical support to resolve issues, but are generally not user friendly format.
vcenter2debug-x.log.y—Debug log used by technical support
jetty-service.log—Jetty service log, used by technical support
<date/time stamp>.request.log—Log of IP addresses for all Jetty
service requests from clients

Common Errors

The most common errors encountered are:
Unable to communicate with Application Server
Check firewall settings to ensure the Jetty TCP port is enabled.
Verify the cimserver/Pegasus server service is started on the
Application Server. — Verify the Jetty6-Service is started on the
Application Server.
Unable to create/delete objects
Verify the current user ID has correct storage administrator privileges
assigned to their role.
Dell MD Storage Array vCenter Plug-in
41