Dell PS-M4110 Manuel - Sayfa 11
Depolama Dell PS-M4110 için çevrimiçi göz atın veya pdf Manuel indirin. Dell PS-M4110 22 sayfaları. Blade array
FTOS (conf-if-range-fo-1/33-37) port-channel-protocol LACP
FTOS (conf-if-range-fo-1/33-37-lacp) port-channel 1 mode active
FTOS (conf-if-range-fo-1/33-37) #no shutdown
FTOS (conf-if-range-fo-1/33-37) #exit
FTOS (conf) #exit
FTOS#wr mem
FTOS#conf
FTOS (conf) #interface Port-channel 1
FTOS (conf-if-po-1) # mtu 9216
FTOS (conf-if-po-1) # switchport
FTOS (conf-if-po-1) # no shutdown
FTOS (conf-if-po-1) # exit
FTOS (conf) # exit
FTOS# wr mem
Note: Repeat the same steps on the second switch
5.1.4 Stack configuration (Non-LAG configurations):
FTOS>en
FTOS#
FTOS#conf
FTOS (conf) #stack-unit 1 stack-group 0
FTOS (conf) #stack-unit 1 stack-group 1
Note: Repeat the same steps on the second switch. Stack-unit number may differ as per the user
settings