Dell Dell SC Series Yapılandırma Kılavuzu - Sayfa 10
Anahtar Dell Dell SC Series için çevrimiçi göz atın veya pdf Yapılandırma Kılavuzu indirin. Dell Dell SC Series 11 sayfaları.
4
Configuring VCS ID and Rbridge-ID (optional)
Refer to Brocade documentation for details on VCS and Ethernet fabric. The following commands show
the steps to configure the rbridge-id and VCS id to 2 on a switch. The VDX 6740 is in Fabric Cluster mode
by default and configuration change is not required for the mode.
sw0# show vcs
Config Mode
VCS Mode
VCS ID
Total Number of Nodes
Rbridge-Id
Fabric Status
--------------------------------------------------------------------------------
------------------------------
2
Online
sw0# vcs vcsid 2
This operation will change the configuration to default and reboot the switch.
Do you want to continue? [y/n]:y
Note: The switch will reboot.
sw0# vcs rbridge-id 2
This operation will change the configuration to default and reboot the switch.
Do you want to continue? [y/n]:y
Note: The switch will reboot.
10
SCG2013 | Brocade VDX 6740 Switch Configuration Guide for Dell SC Series SANs
: Local-Only
: Fabric Cluster
: 1
: 1
WWN
HostName
>10:00:50:EB:1A:2D:F2:64*
sw0
Management IP
VCS Status
77.77.77.77
Online