Dell PowerConnect 3448 Sürüm Notları
Viewing Statistics
Viewing
RMON Statistics
Viewing RMON
History Table

Corrections and Additions to the CLI Reference Guide

CLI Command

Copy

spanning-tree pathcost method

spanning-tree portfast

service cpu-utilization

switchport access vlan

switchport general allowed vlan

switchport general pvid

show vlan

show vlan mac-to-vlan

power inline

System Firmware Version 2.0.0.20
PowerConnect 3424/3448 Release Notes
Oversize Packets – Number of oversized packets (over 1632 octets)
received on the interface since the device was last refreshed.
Jabbers – The number of packets received during this sampling interval
that were longer than 1632 octets (excluding framing bits but including
FCS octets), and had either a bad Frame Check Sequence (FCS) with an
integral number of octets (FCS Error) or a bad FCS with a non-integral
number of octets (Alignment Error).
Dropped Events – counter is not supported.
(and not as indicated)
Description of Change
The range of the source-url and destination-url in the command copy
source-url destination-url should be 1 – 128 characters.
In the command
spanning-tree pathcost method {long | short}
specifies that defaults are per long pathcost method, and short specifies
that defaults are per short pathcost method.
The default path cost for interface are per the path cost method specified.
The following indicates default path cost per method selected:
Interface
Port-channel
Gigabit Ethernet
Port
Fast Ethernet Port
Ethernet (10 Mbps)
Syntax is changed to:
spanning-tree portfast [auto]
auto – Specifies that the software waits for three seconds (with no BPDUs
received on the interface) prior to transitioning the interface to PortFast
mode.
The default mode is auto.
By default, the cpu-utilization collection is enabled.
An interface can only be assigned to "dynamic VLAN" if it is not a member
of any VLAN except the default VLAN.
An interface can be assigned to "dynamic VLAN" only if it is in access
mode. Note that the default port mode for all ports is "access".
When an interface in General Mode is configured with a PVID, this
interface is not automatically added as a member of the VLAN with that
VID.
Syntax of command is "show vlan mac-to-vlan" and not as documented.
The syntax of the command is not as written, and should be power inline
[auto | never]
Subject to Change Without Notice