Dell PowerConnect M8024 Ürün Yazılımını Yükseltme - Sayfa 14
Anahtar Dell PowerConnect M8024 için çevrimiçi göz atın veya pdf Ürün Yazılımını Yükseltme indirin. Dell PowerConnect M8024 24 sayfaları. Upgrading from version 2.x.x.x or 3.x.x.x or 4.x.x.x or 5.x.x.x to 5.1.9.3 firmware
Ayrıca Dell PowerConnect M8024 için: Yayın Notu (9 sayfalar), Sürüm Notları (27 sayfalar), Yapılandırma Kılavuzu (21 sayfalar)
Upgrading PowerConnect Switches from Version 2.x.x.x or 3.x.x.x or
4.x.x.x or 5.x.x.x to 5.1.9.3 Firmware
2. Upgrade CPLD from console.
console#dev cpldUpdate
Device #1 Silicon ID is ALTERA04(01)
erasing MAXII device(s)...
erasing MAXII UFM block...
erasing MAXII CFM block...
programming CFM block...
programming UFM block...
verifying CFM block...
verifying UFM block...
DONE
CPLD update exited with a return code of 0
error_address 180300310, exit_code 0, format_version 2
value = -1 = 0xffffffff
3.
Power cycle the switch - Hard reboot required. Power disconnected for 10 seconds. Each unit of the
stack will require a hard reboot
4. Repeat Steps 1 through 3 on each member unit in the Stack of PC8024/PC8024F switches. The above
CPLD update instructions are allowed to run from serial console prompt (for example.
CLI unavailable - please connect to master on Unit 1)>devshell cpldTest)
the stack even if it's not the Master switch.
5. Verify the updated CPLD version after switch power cycle.
console#dev cpldTest
Board Type
Board Version
CPLD Revision
RPS2 Present
RPS2 Status
RPS2 Temperature
RPS2 Fan Status
RPS1 Present
RPS1 Status
RPS1 Temperature
RPS1 Fan Status
Port
SFP Status
----
----------
1
Present
2
Present
3
Not Present
4
Not Present
5
Not Present
6
Not Present
7
Not Present
8
Not Present
9
Present
10
Present
11
Not Present
12
Not Present
13
Not Present
14
Not Present
15
Not Present
16
Not Present
17
Not Present
18
Not Present
19
Not Present
20
Not Present
21
Not Present
22
Not Present
23
Not Present
24
Not Present
Fan1 Status
Fan2 Status
Fan3 Status
value = 36 = 0x24
.
: Campbell 24F
: 2
: 6 (0x6)
: Working
: Normal
: Working
: Working
: Normal
: Working
Link Status
Tx Power
-----------
--------
Up
Enabled
Up
Enabled
Down
Disabled
Down
Disabled
Down
Disabled
Down
Disabled
Down
Disabled
Down
Disabled
Up
Enabled
Up
Enabled
Down
Disabled
Down
Disabled
Down
Disabled
Down
Disabled
Down
Disabled
Down
Disabled
Down
Enabled
Down
Enabled
Down
Disabled
Down
Disabled
Down
Disabled
Down
Disabled
Down
Disabled
Down
Disabled
: Working
: Working
: Working
Page 11
(Unit 2 -
of all members in