Dell PowerConnect PC7048P Teknik Beyaz Kitap - Sayfa 31
Anahtar Dell PowerConnect PC7048P için çevrimiçi göz atın veya pdf Teknik Beyaz Kitap indirin. Dell PowerConnect PC7048P 34 sayfaları. Stacking gigabit ethernet switches
Ayrıca Dell PowerConnect PC7048P için: İstifleme Talimatları (37 sayfalar)
Stacking Dell PowerConnect 7000 Series Switches
NSF Example 1
Assume Unit 1 is the stack manager and Unit 2 is the standby switch. The following scenarios illustrate
how the network recovers when Unit 1 is powered down.
•
With NSF disabled: Unit 2 takes over as manager with a cold restart and clears the
hardware tables. The video stream stops on Hosts 2 and 3 for at least 30 seconds as the
OSPF adjacency is rebuilt, multicast routes are relearned, and spanning tree
reconverges.
•
With NSF enabled: Unit 2 takes over as manager with a warm restart. OSPF graceful
restart keeps the adjacency with Router 1 up and Router 1 continues to forward to the
stack. There is no perceivable outage of the video stream through the stack.
NSF Example 2:
Assume Unit 2 is the stack manager and Unit 3 is the standby switch, and both ports are active on the
LAG. In this scenario, NSF is enabled and the initiate failover command is used.
•
Because the unit with the root port goes down, the stack stops forwarding until the
spanning tree control plane comes back and places the link on Unit 3 in the forwarding
state (about 3 seconds).
Page 29