Dell PowerEdge 6400 Manuel - Sayfa 14

Anahtar Dell PowerEdge 6400 için çevrimiçi göz atın veya pdf Manuel indirin. Dell PowerEdge 6400 15 sayfaları. Wake-on-lan (wol) support on dell servers
Ayrıca Dell PowerEdge 6400 için: Raf Kurulumu (37 sayfalar), Yükseltme Kurulum Kılavuzu (42 sayfalar), Raf Kurulumu (34 sayfalar), Kurulum Kılavuzu (42 sayfalar), Kurulum Kılavuzu (37 sayfalar), Manuel (10 sayfalar), Kurulum (4 sayfalar), Montaj ve Kurulum (32 sayfalar), Manuel (10 sayfalar)

Dell PowerEdge 6400 Manuel
3
Section
Enabling WOL under Novell
and 6.x
NICs and LOMs from Dell have WOL disabled by default. Having more than 
one device enabled for WOL in a system can overload the 3.3‐volt auxiliary 
power supply and cause it to malfunction.  Dell strongly recommends that only 
one device be enabled for WOL per system. To enable WOL, create a DOS‐
bootable floppy and copy the utility, listed in the Tools section above, specific to 
the WOL device to it from the Dell Open Management Server Assistant or 
download it from http://support.dell.com.  
 
The steps to enabling WOL under NetWare 5.x and 6.x are as follows: 
  
1. Boot the system using the DOS floppy, and run 'IBAUTIL.EXE', 
'UXDIAG.EXE –t ABCD' or 'B57UDIAG.EXE –t ABCD'.  These programs will 
display the physically installed adapters and the status of each card's WOL 
setting.  UXDIAG.EXE is for NetXtreme II devices and B57UDIAG.EXE is for 
NetXtreme I devices. 
 
2. Choose the NIC for WOL, record its MAC address, and note its number on 
the left hand side of the display.   
 
 
3. Reboot the system and start the NetWare server.  If the most recent Dell‐
provided drivers are not installed, install them.   
 
4. For Intel based NICs or LOMs no modification is necessary, the driver is set 
up for WOL by default.  To turn off WOL, use the 'pmedisable=1' key word 
in the load line.  Set 'pmedisable=0' to re‐enable WOL 
 
5. For Broadcom based NICs or LOMS, the keyword 'magicp=1' must be used 
to enable the driver for WOL.  Setting 'magicp=0' disables WOL, disabled is 
the default. 
October 2007
a. Enable Intel WOL by typing 'ibautil –nic=X –wole' where X is the 
number of the NIC in the display.   
b. Enable Broadcom NX1 WOL by typing 'b57udiag –w 1 –c X' where X 
is the number of the NIC in the display. 
c.
Enable Broadcom NX2 WOL by typing 'uxdiag –c  X –wol 1' where X 
is the number of the NIC in the display. 
 
Page 14
NetWare
®
®
Dell Enterprise Product Group
5.x