Dell S6000-ON Kurulum Kılavuzu - Sayfa 24

Anahtar Dell S6000-ON için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Dell S6000-ON 41 sayfaları. Open networking
Ayrıca Dell S6000-ON için: Başlangıç Kılavuzu (26 sayfalar), Sorun Giderme Kılavuzu (29 sayfalar)

Dell S6000-ON Kurulum Kılavuzu
The S6000–ON supports two hot-swappable PSUs with integrated fans that provide cooling for the system.
The S6000–ON supports AC power supplies with two air-flow directions—I/O to PSU and PSU to I/O. Two PSUs are required for full
redundancy, but the system can operate with a single PSU.
NOTE:
If you use a single PSU, install a blank plate in the other PSU slot. Dell EMC recommends using power supply 2 (PSU2) as
the blank plate slot.
The PSUs are field replaceable. When running with full redundancy—two power supplies installed and running, you can remove and replace
one PSU while the other PSU is running without disrupting traffic.
WARNING:
ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap
when handling the S6000–ON and its components.
WARNING:
To prevent electrical shock, ensure that the S6000–ON is grounded properly. If you ground your equipment
incorrectly, excessive emissions may result. To ensure that the power cables meet your local electrical requirements, use a
qualified electrician.
Topics:

Components

AC power supply installation
AC power supply replacement
S6000–ON system installation
Components
The following power supply options are available for the S6000–ON:
AC power supply with integrated fan
AC power supply with integrated reverse flow fan
Power supply 1 (PSU1) is on the left side of the chassis; power supply 2 (PSU2) is on the right side of the chassis.
Figure 12. S6000–ON with PSU
1
PSU 1
2
Fan Modules 1 through 3
24

Power supplies

Power supplies
6