Table 21: User Store File Server RAID Guidelines
Application
File – User file
store
Recommended:
RAID 5 – Recommended for file servers that require maximum storage capacity and
moderate data protection and performance.
RAID 50 – Recommended for those solutions that require a balance between storage
capacity and performance.
RAID 6 – Recommended for file servers that require maximum storage capacity,
enhanced data protection, and moderate performance.
RAID 60 – Recommended for those solutions that require a balance between storage
capacity and performance with maximum data protection.
Possible:
RAID 1 – Possible solution for situations that do not require high storage capacity.
RAID 10 – Possible solution for situations that require greater availability and
redundancy but not as much disk capacity.
RAID 0 – While this solution is not redundant, RAID 0 may be useful for file servers that
require better performance and maximum storage capacity; for example, where
backups are expected to maintain data in the event of a failure.
Concatenated – This solution could be used for situations that require maximum
scalability as physical disks could be added as storage needs grow. For file servers that
can afford some downtime and rely on backups to restore data, this could be a solution.
Table 22: User Store File Server Enclosure Guidelines
Application
File-User File Store
Recommended:
MD1000 – Recommended for user file store file servers in which capacity is highest
priority.
MD1120 – Recommended for user file store file servers where performance and power
efficiency are high priority.
PAGE 36
RAID Level
Concatenated 0
Recommended
Enclosure
3U / 15 x 3.5" drive
Recommended
1
10
5
Not Recommended
MD1000
Not Recommended
VER A02
6
60
50
Possible
MD1120
2U / 24 x 2.5" drive
Possible
6/16/2008