Miele G 2120 Manuel - Sayfa 13
Bulaşık Makinesi Miele G 2120 için çevrimiçi göz atın veya pdf Manuel indirin. Miele G 2120 46 sayfaları.
Ayrıca Miele G 2120 için: Manuel (14 sayfalar)
G 1xxx/G 2xxx
Options:
Function
Software version ID check
Reset
Water hardness setting
Dispensed rinse aid
quantity setting
Buzzer on/off
Adjust Sensor Wash
program
Resetting standard
settings
Programming
Do not press the Tab
button. The "Tab" LED is
not lit.
Press the Tab button 1x.
The "Tab" LED flashes 1x
rapidly intermittently.
Press the Program button
to reset all standard
settings.
Press the Tab button 2x.
The "Tab" LED flashes 2x
rapidly intermittently.
1
Press the Program button
as appropriate to set the
desired water hardness.
Press the Tab button 3x.
The "Tab" LED flashes 3x
rapidly intermittently.
Press the Program button
as appropriate to make the
desired setting.
Press the Tab button 4x.
The "Tab" LED flashes 4x
rapidly intermittently.
Press the Program button
as appropriate to make the
desired setting.
Press Tab 5x. The "Tab"
LED flashes 5x rapidly
intermittently. Press the
Program button to change
the setting.
Press Tab 12x. The "Tab"
LED flashes 1x slowly and
2x rapidly intermittently.
Press the Program button
to reset all settings back to
their factory values.
13
Technical Information
Display
The display shows the software
version ID no. in consecutive digits
(e.g., -1304).
This programmable function can be
used to reset all modifiable
parameters to their standard
settings. The display shows p and a
digit alternately: p0 = Non-standard
settings have been made; p1 = All
settings reset to standard settings
or no modifications have been
made.
The display shows p and the digit/s
of the set value alternately.
Setting range: p1 to p70; see Table
2
9.
The display shows P and a digit
alternately: e.g., P3 (standard
setting) indicates a dispensed
quantity of 0.1 fl.oz. (3mL). Setting
range: 0 - 0.2 fl.oz. (0 - 6 mL). See
Table 10.
The display shows p and a digit
alternately: p0 = Buzzer off; p1 =
Buzzer on.
The display shows P and a digit
alternately. Setting options: P0 =
Standard program cycle (factory
setting); P1 = Adjusted program
cycle. The Sensor Wash program
can be adjusted in this parameter to
deal with stubborn soiling (or
otherwise low overall soiling). If this
option is selected, the main wash
temperature is increased to 131°F
and, as a result, the program
duration is extended.
This programmable function can be
used to reset all customer-modified
parameters back to their standard
settings. The display shows P and a
digit alternately. P0 = Settings have
been modified; P1 = All settings reset
to standard settings or no
modifications have been made.