Allmatic AM900ECO Kurulum Kılavuzu - Sayfa 3
Kontrol Ünitesi Allmatic AM900ECO için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Allmatic AM900ECO 8 sayfaları. Programmable control unit for rolling shutters
3
4
5
6
7
8
4. Signalling led
"Power On": lighted when the control unit is powered.
"Photo": lighted if the photocell contact is closed.
5. Preliminary checks
Preliminary checks must be executed by qualified personnel only, paying the maximum attention . The correct wiring of the motor is very impor-
tant for a correct functioning of the automation.
After having checked the wirings and verified that there are
no short circuits, unlock the motor and power the system.
1
Press the cabled button open.
2
Press the cable button close.
3
NOTE - when the control unit will be activated, it emits 2 beeps to signal the correct start up.
6-1622601 REV.02
22/09/2021
Connect the neutral of the motor to the
clamp 12 of the control unit.
Connect the phase "1" of the motor to the
clamp 13 of the control unit.
Connect the phase "2" of the motor to the
clamp 14 of the control unit.
Connect the NORMALLY CLOSED contact
of the STOP to the clamp 1 and 2 of the
terminal board.
WARNING : jumper the input 1 to the
input 2 if not used.
Connect the OPEN button between
clamp 2 and 3 of the terminal board. Leave
it open if not used .
Connect the
CLOSE button between the
clamp 2 and 4 of the terminal board. Leave it
open if not used.
Connect the NORMALLY CLOSED contact
of the photocell (PHOTO) between the clamp
2 and 5 of the control unit.
WARNING: jumper the input 2 to the input
5 if not used.
Connect
the
power
supply
accessories to the clamp 6 and 7 of the
terminal board.
ITA
ENG
FRA
Check that the motor wiring is compliant with the
installation. To do this, follow the procedure of the
preliminary checks
If the STOP input is open, then this causes the
immediate stop of the automation
The activation of the OPEN button gives an opening
the
impulse to the automation.
The activation of the CLOSE button gives a closing
impulse to the automation.
The PHOTOCELL (PHOTO) can cause the STOP
of the automation or the motion inversion .
See chap.9
of
the
WARNINGS: the control unit gives a voltage of 24
Vdc.
"Stop": lighted if the contact stop is closed.
Check the status of the signalling LED "photo", "stop"
considering that all the inputs normally closed must have
the correspondent led lighted.
The automation opens. Correct functioning.
The automation closes, inverse the connections between
the clamp 13 and 14.
The automation closes. Correct functioning.
The automation closes, inverse the connections between
the clamp 13 and 14.
ESP
DEU
POR
3 / 8