Allmatic BAXS900 Manuel - Sayfa 10
Kontrol Ünitesi Allmatic BAXS900 için çevrimiçi göz atın veya pdf Manuel indirin. Allmatic BAXS900 13 sayfaları. For rolling shutters
13. WARNING/DIAGNOSIS SIGNALS
For warnings and error states of the BAXS900, follow these steps:
Type of anomaly found
Safety check /
3 blinks
Safety Error /
Motor ON
Safety check /
Fast
Safety Error /
blinking
Safety check /
Blinking
Safety Error /
during start
up phase
Blinking
Safety check /
Safety Error /
5 seconds
Safety check /
fast blinking
Safety Error /
Motor ON
Motor ON
Blinking
Safety Error /
Blinking
Motor ON
14. TECHNICAL SPECIFICATIONS
Power Supply
Motor
Courtesy Light (Integrated)
Courtesy Light (Additional)
Output Aux
Remote Command
Radio Reciever
Operating Temperature
Degree of Protection Box
10 / 12
Leds
Problem
Led verification during the start
up phase
Autotest failure
Radio memory damaged
Software autotest failure
Software autotest failure
Intervention of thermal
protection
Autotest circuit damaged
Solution
If an R.CO.O card is installed, check
DIP1 = 0N and restart BAXS900
Need to delete all transmitters
Restart BAXS900
BAXS900 automatic restart
Wait for the control unit to be
reactivated
Check motor connection, if it is ok,
please contact service
Voltage
Frequency
Protection Fuse (F1)
Voltage
Frequency
Type
Power (Max)
Voltage
Frequency
Power
Type
Voltage
Frequency
Power (Max)
Voltage
Power (Max)
Voltage of control
Frequency
Modulation
Type of Code
230Vac
50/60Hz
6.3A FAST
230Vac
50/60Hz
ACIM 2-phases
1000W
230Vac
50/60Hz
2W
E14 Led
230Vac
50/60Hz
500W
24Vdc
6W
24Vdc (isolated) SELV
433.92MHz
00K
Rolling CODE - 66bit
-10°C...+55°C
IP65
6-1622623 rev. 3