6. Menu
Entering the menu:
To enter the base menu settings keep pressed the MENU button for at least one second
To enter the advanced menu settings keep pressed the MENU button for at least five seconds
Navigation into the menu:
It is possible to move from an entry to another one using UP[+] e DOWN[-] buttons,
To change a parameter keep pressed the MENU button for at least 1 second until the parameter begins blinking,
so release the key.
Use UP[+] and DOWN[-] buttons to change the parameter
At the end keep pressed MENU for al least 1 second until the parameter stops blinking to save the change.
A quick pressure of the menu key is enough to leave a menu
6.1 Base settings menu:
MENU
tCL
tCL
tCL
tCL
Auto reclosing time (0 = disabled)
ttr
ttr
ttr
ttr
Auto reclosing time after transit(0 = disabled)
Trq
Trq
Trq
Trq
Motor torque (running torque)
Slowing down mode
SSL
SSL
SSL
SSL
0 = normal
1 = fast with more torque
Step by step configuration
0 = normal (OP-ST-CL-ST-OP-ST...)
1 = alternated STOP (OP-ST-CL-OP-ST-CL...)
SbS
SbS
SbS
SbS
2 = alternated (OP-CL-OP-CL...)
3 = condominium – timer
4 = condominium with immediate auto reclosing
Soft start
SSt
SSt
SSt
SSt
0 = disabled
1 = enabled
DLY
DLY
DLY
DLY
Second wing delay
Amplitude of slowing down (0 = disabled)
LsI
LsI
LsI
LsI
P = personalized during learning
0...100% = percentage of stroke
ASL
ASL
ASL
ASL
Anti slip
Number of motors
nmt
nmt
nmt
nmt
1 = 1 motor
2 = 2 motors
6-1622176
rev.05
01/03/2019
DESCRIPTION
ITA
ENG
FRA
SELECTABLE
ESP
DEU
POR
Ex. Base menu
Ex. Advanced menu
VALUES
DEFAULT
min-max
0-900
0
0-30
0
10-100
100
0-1
1
0-4
0
0-1
0
0-300
2
0-100
15
0-300
0
1-2
2
UNITS
s
s
%
s
%
s
6 / 12