Safety regulations prohibit the fitting
of this cooker hood over a solid fuel
stove.
For safety reasons a
must be maintained be-
tween the top of the hob / cooker
and the bottom of the cooker hood:
– 450 mm above electric hobs /
cookers
– 650 mm above gas hobs / cookers
– 650 mm above an open grill
from our range.
See "Warning and Safety instruc-
tions" for further information.
A distance of 650 mm may be pref-
erable above electric hobs / cookers
to give more working space.
When deciding dimension
that the minimum specified safety dis-
tance between the hob / cooker and the
cooker hood is maintained. If the hood
is fitted flush to the ceiling make sure
that the remaining distance to the ceil-
ing is not greater or less than appliance
height .
Recirculation
= 820 – 1110 mm
Extraction
= 800 – 1020 mm with extraction
through the wall.
= 730 – 1020 mm with extraction
through the ceiling.
To fit the tower, distance
top of the tower and the ceiling must be
at least 20 mm.
ensure
between the