Miele DA 239 Kullanım Talimatları Kılavuzu - Sayfa 24

Havalandırma Davlumbazı Miele DA 239 için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Miele DA 239 32 sayfaları.

Miele DA 239 Kullanım Talimatları Kılavuzu
Installation

Motor unit

(only for appliances with an integrated
fan)
Fit the motor unit onto the screws.
Adjust the motor unit and secure.
With an 8 mm dia. bit, drill two holes
through the holes of the motor unit re-
taining plate in the wall and then
press the S 8 plugs into the holes.
24

Control unit

(only for EXT models)
With EXT models (external fan), the
control unit is fitted instead of the
motor unit.
Use the connection cable with 6 pole
plug to connect the cooker hood and
the external fan.
The non-return flap is integrated on
these models.
Only for DA 237:
If the height of the room requires utilisa-
tion of the maximum total height of the
cooker hood, the additional retaining
plate must also be fitted to ensure opti-
mum unit stability.
Fit the retaining plate to the wall
350 mm above the motor unit, using
two S 8 plugs and two 5 x 40 mm
screws.