When using the cooker hood at the
same time as another heating ap-
pliance which depends on the air in the
room, (e.g. gas, oil or coal fired
heaters, continuous flow or other water
heaters, gas cooker, gas hob or gas
oven) special care must be taken, as
the action of the cooker hood extracts
air from the room, which these types of
heater need for combustion.
In order to ensure safe operation, and
to prevent the gases given off by the
heating appliances from being drawn
back into the room when the extractor
and the heater are in operation simulta-
neously, an underpressure in the room
of 0.04 mbar (4 pa) is the maximum
permissible.
Ventilation can be maintained by air in-
lets which cannot be blocked, in win-
dows, doors and outside wall vents, or
by other technical measures, such as
ensuring that the extractor can only be
switched on when the heating ap-
pliance is switched off or vice-versa.
N.B.: The overall ventilation condition of
the dwelling must be taken into ac-
count.
If in any doubt, the advice of a compe-
tent builder or, for gas, a "Corgi" instal-
ler (gas fitter) must be sought.
Warning and Safety instructions
only for appliances with external fans
For appliances with an external fan
motor fitted (EXT models) the con-
nection of the two units must be made
using the connection cable and the
plug connectors. Make sure the correct
combination of the two appliances has
been selected.
Disposal of an old machine /
appliance
Before discarding an old machine
or appliance render it useless.
Ensure that disconnection from the
mains supply is carried out by a com-
petent person and that the cable is
also removed from the appliance to
prevent misuse.
The manufacturer cannot be held re-
sponsible for any damage caused
by non-observance of these instruc-
tions.
7