Allmatic INVERTER COMPACT Talimatlar - Sayfa 5
Garaj Kapısı Açıcı Allmatic INVERTER COMPACT için çevrimiçi göz atın veya pdf Talimatlar indirin. Allmatic INVERTER COMPACT 20 sayfaları.
2. CONNECTIONS
Front view
D1
M1
IL
ME
F4
F1
F2
1-2
ACCESSORIES OUTPUT 24Vac 10W.
PHOTOCELLS POWER SUPPLY
Connect the clamp 3 of the control unit to the clamp + of the
power supply of the photocells receiver.
Connect the clamp 4 of the control unit to the power supply
3-4-5
clamp - of the photocells receiver and of the transmitter.
Connect the clamp 5 of the control unit to the power supply
clamp of the trasnmitter of the photocells
SAFETY EDGE INPUT
Connect the contact NORMALLY CLOSED of the SAFETY EDGE
6-15
between the clamps 6 and 15 of the terminal board.
ATTENTION: jumper the inputs if not used
PHOTOCELL INPUT
Connect the NORMALLY CLOSED contact of the photocell
7-15
(PHOTO) between the clamps 7 and 15 of the terminal board.
ATTENTION: jumper the inputs if not used
INPUT CLOSING LIMIT SWITCH
Connect the contact NORMALLY CLOSED of the CLOSING LIMIT
8-15
SWITCH (L.S.CL.) between the clamps 8 and 15 of the control
board
IINPUT OPENING LIMIT SWITCH
Connect the contact NORMALLY CLOSED of the OPENING LIMIT
9-15
SWITCH (L.S.CL.) between the clamps 9 and 15 of the terminal
board.
STOP INPUT
10-15
Connect the contact NORMALLY CLOSED of the STOP between
the clamps 10 and 15 of the terminal board.
PL
E
R
F3
Side View
M3
M2
M1
The photocells test test is activated by the MENU A.
ATTENTION: the control unit gives a voltage of 24 Vdc and can
supply a maximum power of 5W.
For the safety edges test connect the test device of the safety
edge on the power supply pins of the TX (test activated wiht low
logic signal 0Vdc).
Please refer to the manual of the safety edge.
The safety edge mode of opearation can be modified in the
MENU A.
The functioning of the photocells can be modified in the MENU
A
Before activating the installation make sure that the limit
switches are functioning and correctly cabled
Before activating the installation make sure that the limit
switches are functioning and correctly cabled
ATTENTION: Move the DIP STOP on ON position if not used
Board details
M1
Terminal block 1
M2
Terminal block 2
M3
Terminal block 3
P1
Button 1
P2
Button 2
P3
Button 3
Dip switches inputs N.C.
D1
disabling
R
Radio receiver connector
ME
Extractable memory
IL
Input led
PL
Power supply led
E
Encoder (optional)
F1
Fuse 1, Line 230Vac
F2
Fuse 2, inputs
F3
Fuse 3, photocells
F4
Fuse 4, auxiliaries 24V
5 / 20