Allmatic INVERTER COMPACT Talimatlar - Sayfa 8
Garaj Kapısı Açıcı Allmatic INVERTER COMPACT için çevrimiçi göz atın veya pdf Talimatlar indirin. Allmatic INVERTER COMPACT 20 sayfaları.
Close command
CLOSE / COM
M1
Step by step command
SS / COM
M1
M2
COURTESY LIGHT
MAINS
230Vac
M2
4. PROGRAMMING
4.1 Activation and selection of the programming menu
The INVERTER COMPACT control unit it is equipped with 3 user menu (MENU A, MENU B, MENU C), with which you can adjust, program and modify
all the functional parameters. During the programming phases follow the indications shown on the display.
It is advisable to select the language as the first operation:
1. Press the P3 key for 2 seconds.
2. Confirm with the P2 button.
3. Select the desired language by pressing P1 or P3.
4. Confirm with P2.
8 / 20
CLOSE
12
COM
15
SS
12
COM
15
PE
N
L
Partial open command
PAR / COM
M1
MOTOR
M2
M2
FLASH
OUT
CONTATTO PULITO
DRY CONTACT
ELETTROFRENO /
ELETTROSERRATURA
M3
PAR
13
COM
15
W
V
U