Miele KMR1356 G Kurulum Talimatı - Sayfa 7
Havalandırma Davlumbazı Miele KMR1356 G için çevrimiçi göz atın veya pdf Kurulum Talimatı indirin. Miele KMR1356 G 21 sayfaları.
KMR 1135 / KMR 1136
Position
(150 mm + + 150 mm)
For all other Hoods, please consult with manufacturer's instructions
for required distances.
Dimension
min. 36"
(914 mm)
6" + + 6"
37" (940 mm)
30" (762 mm)
Dimensional drawings
Description
Width of cabinet opening
In case of the presence of com‐
bustible material an additional min‐
imum clearance of 6" (each side) is
necessary. Ensure local codes are
observed.
Minimum distance between the top
of the cooking area and the bottom
of an unprotected combustible sur‐
face.
Minimum distance between the top
of the cooking area and the bottom
of the Miele Range Hood (DAR
model with DRxB XL or DRxB XXL
Blower).
43