Miele PDR 518 Çalıştırma ve Kurulum Talimatları - Sayfa 7

Kurutucu Miele PDR 518 için çevrimiçi göz atın veya pdf Çalıştırma ve Kurulum Talimatları indirin. Miele PDR 518 36 sayfaları. Commercial tumble dryers
Ayrıca Miele PDR 518 için: Çalıştırma ve Kurulum Talimatları (38 sayfalar)

Miele PDR 518 Çalıştırma ve Kurulum Talimatları
Do not connect the tumble dryer to the power supply by an extension lead (fire hazard
due to overheating).
Fire hazard. This tumble dryer must not be connected to a controllable socket (e.g. a
timer). There is a risk of the laundry igniting if the tumble dryer's safety cooling-down
phase is interrupted.
The electrical safety of this tumble dryer can only be guaranteed when correctly earthed.
It is essential that this standard safety requirement is observed and regularly tested. If in
any doubt, please have the electrical installation inspected by a specialist. Miele cannot be
held liable for the consequences of an inadequate earthing system.
Unauthorised repairs could result in unforeseen dangers for the user, for which Miele
cannot accept liability. Repairs should only be undertaken by a Miele authorised techni-
cian, otherwise any subsequent damage will not be covered by the warranty.
Faulty components may only be replaced by genuine Miele spare parts. Miele can only
guarantee the safety standards of the appliance when Miele replacement parts are used.
In the event of a fault and for cleaning and maintenance purposes, the tumble dryer
must be disconnected from the power supply. The tumble dryer is only disconnected from
the power supply, if:
- It is switched off at the wall socket or the plug is withdrawn.
- The mains fuse is disconnected.
- The mains fuses have been completely removed.
See also "Installation – Electrical connection".
The tumble dryer must not be used in non-stationary installation sites (e.g. on a ship).
Follow the instructions in "Installation" and "Technical data".
The tumble dryer may only be operated when the ducting has been installed and the
room is sufficiently ventilated.
The vent ducting must never be installed in any of the following flues or shafts:
- Chimneys or smokestacks that are in use.
- Shafts that are used to ventilate installation rooms with fireplaces.
- Flues that are used by third parties.
Smoke or exhaust gas that is fed back into the flue or shaft may be toxic.
Regularly check all components in the vent ducting (e.g. wall pipe, external grille, bends,
elbows, etc.) to make sure air can move through them and to ensure that they are working
properly. Clean components when necessary. Fluff deposits in the vent ducting system will
prevent the air from being extracted properly and, as a result, will stop the tumble dryer
from working properly.
If existing vent ducting is due to be used, it must be checked before being connected to
the tumble dryer.
There is a risk of suffocation and poisoning due to exhaust gases being sucked back if
gas-powered flow heaters, gas-powered room heaters, coal-burning stoves with a flue
connection, etc., are installed in the same room, in the same flat or in neighbouring rooms
and the negative pressure is 4 Pa or more.
Warning and Safety instructions
7