7. Enter the appropriate configuration settings for the following parameters:
#
Setting
3
IP Address
4
Subnet
5
Gateway
7
Transmitter IP Address
8
Transmitter SNMP Port
9
SNMP Read Community
String
10 SNMP Write Community
String
11 SNMP Polling Rate
12 SNMP Timeout
13 ARC Plus IP Address
14 ARC Plus Plus-X Port
15 SNMP Security Code
8. Enter 99 and press <Enter> to save your changes and reboot the PlusConnect.

Additional SNMP Parameters

The main menu allows configuration of additional parameters beyond those described in the table
above. The default values for these entries are appropriate for most installations. If you have made
specific changes to the SNMP functionality of your transmitter, you should change the corresponding
parameters using the PlusConnect telnet configuration tool.

Setting the Password

Changing your password is strongly recommended. The PlusConnect password is used to access the
telnet configuration menu. To change the password, use option #16: Set Password.

Uploading New Firmware

To upload new firmware to the PlusConnect, use option #18: Upload Firmware. When prompted to
start the firmware upload, enter "Y" for yes. The system will respond with the following message:
To load firmware run:
tftp [IP Address] put [firmware.hex]
Open a command prompt in Windows and type the specified command, replacing [IP Address] with the
IP address of your PlusConnect unit, and [firmware.hex] with the file name of the new firmware file.
Once the TFTP process is complete, your unit will reboot and run the new firmware. You can confirm
the upload was successful by opening a telnet session and observing the firmware version from the log
on prompt.
PlusConnect™ GatesAir ZXA Installation and Operation Manual
Description
The IP address you want to assign to the PlusConnect unit
The subnet mask for your LAN
The gateway for your LAN
The IP address of your GatesAir ZXA series transmitter
Normally 161
Normally public
Normally private
The rate at which new samples are requested
Length of time the PlusConnect will wait for response
The IP address of your ARC Plus unit
The Plus-X port number configured on your ARC Plus (typically
45000)
The security code used for SNMP commands. See your
transmitter documentation for more information.
5