Burkert 0131 Kullanım Talimatları Kılavuzu - Sayfa 12

Kontrol Ünitesi Burkert 0131 için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Burkert 0131 16 sayfaları. 2/2- or 3/2-way solenoid valve
Ayrıca Burkert 0131 için: Kullanım Talimatları Kılavuzu (16 sayfalar)

Burkert 0131 Kullanım Talimatları Kılavuzu
Procedure:
Tighten cable plug (for permitted types see data sheet), observing
max. torque 1 Nm.
Check that seal is fitted correctly.
Connect protective conductor and check electrical continuity.
Authorized cable plug
e.g. Type 2508 or other suitable
cable plug in accordance with
DIN EN 175301-803 Form A
max. 1 Nm
Seal
max. 1 Nm
Seal
6
MAINTENANCE, TROUBLESHOOTING
6.1
Safety instructions
WARNING!
Risk of injury from improper maintenance!
▶ Maintenance may be carried out by authorized technicians only
and with the appropriate tools!
Risk of injury from unintentional activation of the system and an
uncontrolled restart!
▶ Secure system from unintentional activation.
▶ Following maintenance, ensure a controlled restart.
6.2
Malfunctions
If malfunctions occur, check whether:
• the device has been installed according to the instructions,
• the electrical and fluid connections are correct,
• the device is not damaged,
• all screws have been tightened,
• the voltage and pressure have been switched on,
• the pipelines are clean.
english