Slip Fitter Models: F1*******S****
Make proper connections inside the junction
base of the slip fitter and tuck any excess
wiring into the junction base. Assure none of
the wiring can be pinched when replacing
cover.
Install the cover and tighten the hardware
using the recommended torque to assure a
proper seal.
Torque: 1 in-lb [1.4 N-m]
Electrical Connections
Bracket Models: F********(E/F)****
The terminal block is suitable for multi-
stranded or single core wires. The parameters
can be found in Technical Data.
Push Down Terminal Models: F**********U**
Push down at the 'cross point', insert wire, and
release.
Conductor Range
0.5-4 mm² [20-12 AWG]
9 mm [0.35 in.]
Screw Down Terminal Models: F**********V**
For input power terminal block, loosen
terminal screw, insert wire, and tighten screw.
Conductor Range
0.5-6 mm² [20-10 AWG]
10 mm [0.39 in.]
For dimming & Dali lines, push down at the
'cross point', insert wire, and release.
Conductor Range
0.5-4 mm² [20-12 AWG]
9 mm [0.35 in.]
Slip Fitter Models: F1(E/U)******S****
All slip fitter models contain lever nut
connectors inside the junction base to make
appropriate connections.
Conductor Range
0.5-4 mm² [20-12 AWG]
9 mm [0.35 in.]
Single Phase Connections
The connections are marked on the terminal
block or on a label and are presented in the
table below.
9100FLM00901 REV A
Page 5 of 9
ProSite Floodlight for CID2/CIID2/CIII
SYMBOL
N
L
N
L
L2
L1
DIM +
DIM -
DALI
DALI
0-10 VDC Dimming (If Applicable)
Dimming is controlled by means of a 0-10
VDC signal (to be provided by the installer) to
control the level of dimming. At 10 volts, the
output of the unit is 100%; at 0 volts, the output
will shut off. The DC dimming voltage should
not exceed 15 VDC. Increasing the voltage
from 10 VDC to 15 VDC will not result in
additional light output.
WARNING: Never connect the dimming wires
to the Hot or Neutral supply wires.
Strip Length
Variable Voltage Control
An analog 0-10 V active dimmer may be
connected to the two wires to control the
light output of the fixture. Multiple lights may
be connected to the same dimmer, as long
as the maximum current rating of the dimmer
Strip Length
is not exceeded.
See table for current sinking capabilities of
the
dimmer.
approximately linearly with control voltage,
with 10 V corresponding to 100% light output.
Strip Length
Part Number
F1************
F2*****(F/H)******
F2*****(L/N)******
Strip Length
COLOR
CONNECTION
120-277VAC
GREEN/
EARTH/
YELLOW
GROUND
WHITE
NEUTRAL
BLACK
LIVE
120-250VDC
GREEN/
EARTH/
YELLOW
GROUND
WHITE
-
BLACK
+
347-480VAC
GREEN/
EARTH/
YELLOW
GROUND
RED
LIVE 2
BLACK
LIVE 1
CONTROLS
VIOLET
DIMMING +
GREY
DIMMING -
ORANGE
DALI
ORANGE
DALI
Light
output
will
vary
Current
0.5 mA
0.5 mA
1.0 mA
Dialight, 1501 Route 34 South, Farmingdale, NJ, USA 07727
Tel: +1 732 919 3119 Fax: +1 732 751 5778
NOTE: Simply shorting the two wires together
will cause the light to shut off.
WARNING: Improper installation, operation,
or maintenance of this luminaire may result in
the invalidation of the warranty, certificate,
or declaration of conformity.
Maintenance / Inspection
This LED luminaire should require a minimum
amount of maintenance. If any unforeseen
repairs are required, please contact Dialight
or its authorized representative.
Within
the
scope
of
maintenance
inspection routine the following should be
included:
Protective hoses should be covering the
connection cables.
Cable entries must be free of corrosion.
The lens should be cleaned periodically as
needed to ensure continued photometric
performance. Clean the lens with a damp,
non-abrasive,
lint
free
sufficient, use mild soap or a liquid cleaner.
Inspect the luminaire to ensure that it is free
of any obstructions or contamination (i.e.
excessive dust build up). Clean with a non-
abrasive cloth if needed.
Perform visual mechanical and electrical
inspections
on
a
regular
recommend routine checks to be made
on a yearly basis. Frequency of use and
environment should determine this.
It is recommended to follow an Electrical
Preventive
Maintenance
described in NFPA 70B: Recommended
Practice for Electrical Equipment.
Repairs / Overhaul / Modification
The equipment must be operated according
to the intended purpose in a perfect and
undamaged condition.
NOTE: Should the luminaire enclosure be
damaged, only a full luminaire replacement
will be permitted. In case of doubt, the
equipment should be returned to Dialight for
inspection/repair.
Disposal & Recycling
When the apparatus is disposed of, the
respective national regulations on waste
disposal should be observed.