ABB ACS880-01 Series Hızlı Kurulum ve Başlatma Kılavuzu - Sayfa 7

Endüstriyel Ekipmanlar ABB ACS880-01 Series için çevrimiçi göz atın veya pdf Hızlı Kurulum ve Başlatma Kılavuzu indirin. ABB ACS880-01 Series 17 sayfaları. Industrial drives
Ayrıca ABB ACS880-01 Series için: Kurulum Kılavuzu (20 sayfalar), Hızlı Kurulum Kılavuzu (14 sayfalar), Manuel (16 sayfalar), Kullanıcı Kılavuzu (18 sayfalar)

ABB ACS880-01 Series Hızlı Kurulum ve Başlatma Kılavuzu

Default I/O connections

Wire sizes:
2
0.5 ... 2.5 mm
(24...12 AWG)
Tightening
torques: 0.5 N·m
(5 lbf·in) for both
stranded and
solid wiring.
1)
Total load capacity
of these outputs is
4.8 W (200 mA /
24 V) minus the
power taken by DIO1
and DIO2.
XPOW External power input
1
2
XAI
Reference voltage and analog inputs
1
+VREF
2
-VREF
3
AGND
4
5
6
7
J1
J2
XAO
Analog outputs
1
2
AGND
3
4
AGND
XD2D
Drive-to-drive link
1
2
3
BGND
J3
XRO1, XRO2, XRO3 Relay outputs
11
12
13
21
22
23
Fault
31
32
33
XD24
Digital interlock
1
2
+24VD
3
DICOM
4
+24VD
5
DIOGND Digital input/output ground
J6
Ground selection switch
XDIO
Digital input/outputs
1
2
XDI
Digital inputs
1
2
3
4
5
6
XSTO
Safe torque off
1
2
SGND
3
4
X12
Safety functions module connection
X13
Control panel connection
X205
Memory unit connection
+24VI
24 V DC, 2 A
GND
10 V DC, R
1...10 kohm
L
-10 V DC, R
1...10 kohm
L
Ground
AI1+
Speed reference 0(2)...10 V, R
200 kohm
AI1-
AI2+
By default not in use. 0(4)...20 mA, R
100 ohm
AI2-
J1
AI1 current/voltage selection jumper
J2
AI2 current/voltage selection jumper
AO1
Motor speed rpm 0...20 mA, R
500 ohm
AO2
Motor current 0...20 mA, R
B
Drive-to-drive link
A
J3
Drive-to-drive link termination switch
NC
Ready
250 V AC / 30 V DC
COM
2 A
NO
NC
Running
COM
250 V AC / 30 V DC
2 A
NO
NC
Faulted(-1)
COM
250 V AC / 30 V DC
2 A
NO
DIIL
Run enable
1)
+24 V DC 200 mA
Digital input ground
1)
+24 V DC 200 mA
DIO1
Output: Ready
DIO2
Output: Running
DI1
Stop (0) / Start (1)
DI2
Forward (0) / Reverse (1)
DI3
Reset
DI4
Acceleration & deceleration select
DI5
Constant speed 1 (1 = On)
DI6
By default not in use.
OUT1
Safe torque off. Both circuits must be
closed for the drive to start.
IN1
IN2
>
in
=
in
<
L
< 500 ohm
L
7