Miller ALT 304 Kullanıcı El Kitabı - Sayfa 19
Kaynak Sistemi Miller ALT 304 için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Miller ALT 304 32 sayfaları.
3-7. Connecting Input Power
Green
1
Y Always connect grounding
conductor first.
= GND/PE
3
2
L1
L2
L3
Green
1
2
L1
L2
1
3
1
Green
6
1
Check input voltage available at
site.
.
The Auto-Line circuitry in this
unit automatically links the
power source to the primary
voltage being applied. A unit
can be connected to any input
power between 208 and 575
VAC.
1
Input And Grounding
Conductors
2
Line Disconnect Device
See Section 3-6.
For single-phase operation:
3
Black And White Input
Conductor
4
Red Input Conductor
5
Insulation Sleeving
6
Electrical Tape
Insulate and isolate red conductor
as shown.
Y Always connect green wire
to supply grounding termi-
nal, never to a line terminal.
Connect black, white, and
red wires (L1, L2, L3) to line
terminals.
4
5
input_9_99 - Ref. 144 221 / Ref. 070 399-C / 802 722
OM-2231 Page 15