Miller Axcess 675 Kullanıcı El Kitabı - Sayfa 33

Kaynak Sistemi Miller Axcess 675 için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Miller Axcess 675 48 sayfaları. Automatic welding interface and arc welding power source
Ayrıca Miller Axcess 675 için: Kullanıcı El Kitabı (48 sayfalar)

8-2. Process Control Module PC4 Diagnostic LED's

8-3. Diagnostic LED's On Process Control Module PC4

LED
Status
1
On
Off
2
On
Off
3,4
On
Off
Indicates −25 volts dc is present on process control module PC4
Indicates −25 volts dc is not present on process control module PC4
Indicates +25 volts dc is present on process control module PC4
Indicates +25 volts dc is not present on process control module PC4
See Network Status Table in Section 8-4
See Network Status Table in Section 8-4
1
Process Control Module PC4
Diagnostic LED's are visible inside unit,
located on PC4 mounted on the top tray.
1
Refer to Section 8-3 for information on
diagnostic LED's.
Reinstall cover after checking diagnostic
LED's.
LED1
LED2
LED3
LED4
Diagnosis
216 956-A / Ref. 803 825-A
OM-217 751 Page 29