4-1. Serial Number And Rating Label Location

The serial number and rating information for the power source is located on the front or the rear of the machine. Use the rating labels to determine
input power requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual.

4-2. Specifications

.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 5-9, 5-10 and 5-11 for information
on connecting input power.
Rated
Voltage
Welding
Range
Output
DC
Model
300 A @ 32
300
(29) Volts
10 − 32
Amp
DC, 100%
Duty Cycle
450 A @ 38
450
(36.5) Volts
10 − 38
Amp
DC, 100%
Duty Cycle
650 A @ 44
650
Volts DC,
10 − 44
Amp
100% Duty
Cycle
*
While idling
( )
Indicates specification differences for CE models

4-3. Environmental Specifications

A. IP Rating
IP Rating
IP21
This equipment is designed for indoor use and
is not intended to be used or stored outside.
B. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
IEC/TS 61000−3−4 can be used to guide parties concerned by the installation of arc welding equipment with an input current greater than 75
A in a low-voltage network.
OM-223 Page 12
.
A complete Parts List is available at www.MillerWelds.com
SECTION 4 − SPECIFICATIONS
Amperes Input at Rated Load Output, 50 or 60 Hz,
Max
OCV DC
200 V
230 V
48
42
44
3.7*
3.2*
72
63
44
3.2*
2.7*
96
33
--
3.2*
Operating Temperature Range
14 to 104 °F (-10 to 40°C)
Three-Phase
380 V
400 V
440 V
460 V
27
25
23
21
1.8*
1.7*
1.6*
1.6*
39
37
33
32
2.6*
2.2*
2.1*
1.4*
58
54
50
48
3.3*
3.0*
2.8*
1.6*
575 V
KVA
KW
17
16.9
12.9
1.3*
1.26*
0.21*
25
25.1
21.1
1.1*
1.09*
0.26*
38
38.2
34.2
1.3*
1.26*
0.35*
Storage Temperature Range
-4 to 131 °F (-20 to 55°C)
IP21 2014−06
ce-emc 5 2014-07