5-9. Connecting 230 Volts Input Power For Diversion 180 Models

Tools Needed:
OM-263920 Page 18
.
A complete Parts List is available at www.MillerWelds.com
1
3
6
1
8
9
L2
230 VAC, 1
!
Installation must meet all Na-
tional and Local Codes − have
only qualified persons make
this installation.
!
Always connect green or
green/yellow conductor
supply grounding terminal
first, and never to a line termi-
nal.
!
Special installation may be re-
quired where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
.
The Auto-Line circuitry in this unit
automatically links the power
=GND/PE Earth
source to the primary voltage be-
Ground
7
ing applied, either 115 or 230
VAC.
1
Input Power Cord.
2
Disconnect Device (switch
2
shown in the OFF position)
3
Disconnect Device Grounding
4
Terminal
4
Disconnect Device Line
L1
Terminals
5
L2
5
Black And White Input
Conductor (L1 And L2)
6
Green Or Green/Yellow
Grounding Conductor
Connect green or green/yellow
grounding conductor to disconnect
device grounding terminal first.
Connect input conductors L1 and L2
to disconnect device line terminals.
7
Over-Current Protection
Select type and size of over-current
protection using Section 5-2 (fused
disconnect switch shown).
Close and secure door on disconnect
device.
device, and place switch in the On
position.
8
Multi-Voltage Plug And Power
Cord Connector (NEMA 6-50P
Plug Shown)
For multi−voltage plug connections,
L1
see Section 5-10.
9
Receptacle (NEMA 6-50R)
(Customer Supplied)
Connect plug to receptacle.
Ref. input4 2012-05 − Ref. 805528-A / Ref. 805467-C
to
Remove
lockout/tagout