13) Do not rely at your work only on the measuring devices of the AC power supply!
14) Use at your work only the tools determined for this purpose!
15) All conductors connected to the device's outlets have to be equipped with a suitable
isolation!
16) In a case the device shows some failure, keep it out of operations and give it to repair
in a specialised service.
17) Do not shorten the outgoing connectors.
18) Do not disassemble the device.
V. Work with the AC Power Supply
Plug the power flex cable to the socket outlet 230 V/ 50 Hz. Put the AC Power Supply in
operation by switching the switch of mains (5). After switching-on is running the test and setup
of the alternating power supply, which is signalised by light up of 888 on all displays (1;8).
During this period is the output of the device blocked (7).
Model AC250K1D (AC250K2D): Approximately after two seconds are the displays switched to
the operational mode and show 0. At the same time is activated the control keyboard (4) and a
short acoustic signal sounds. Output voltage is setup on OV and the output is not connected.
Model AC250K2D-S (AC250K2D-S): Approximately after two seconds are the displays
switched over to the operational mode, where are displayed first the data showing if the
stabilization is switched-on/switched-off (StA ON/OFF) and then is displayed O, eventually the
previous set value – see the text below. At the same time is activated the control keyboard (4)
and a short acoustic signal sounds. Output voltage is setup on OV, eventually on the previous
set value and the output is connected according to its own setup.
The voltage of the AC Power Supply is possible to set in the range between 0V÷255V
with using the keyboard, the minimum possible step is 1 V.
V.I. Voltage output setup
With help of the numeric keys set the requested voltage value. When you start to set the
voltage value, the indicator SET (3) starts to blink. The set value is displayed on the display
SET (1). The preset value confirm by pressing the key ENTER (14). Then the real voltage
value is displayed on the display REAL (8). In a case you set a wrong value, you may cancel it
by pressing the key C (15). If you set the voltage value higher than 255 V, there will be
displayed on the display SET (1) the sign Err. It is necessary to clear the set value by pressing
the key C (15) and then to set a new voltage value. The set value you will bring to the output
by pressing the key OUT (13). Pushing of any key is signalised by a short beep.
V.II. Accurate setting of the voltage output
Due to the fact, that the output voltage is made by transformation of the mains, a different
voltage than the preset could appear thanks to the oscillation of the mains. For accurate
setting you can use the keys UP (10) and DOWN (11) and also the display REAL (8). Pressing
of the key UP (10) increases the voltage, key DOWN (11) decreases the voltage. Longer
pressing of the key caused increasing or decreasing the value by 6V/1s.
- 5 -