Burkert S030 Kullanım Talimatları Kılavuzu - Sayfa 7

Aksesuarlar Burkert S030 için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Burkert S030 11 sayfaları. Inline fitting

Burkert S030 Kullanım Talimatları Kılavuzu
Selection example:
- Specification: if the nominal flow is 10 m
sioning of the optimal flow rate must be contained in 2 to
3m/s
- Answer: on the chart, the intersection of flow rate and
flow velocity gives the appropriate diameter, DN40 or
DN50 for fittings with *.
* For fittings:
- with external threads according to SMS 1145,
- with welding ends according to SMS 3008, BS 4825-1 /
ASME BPE / DIN 11866 series C, DIN 11850 series 2 /
DIN 11866 series A / EN 10357 series A
- with clamp connections according to SMS 3017,
BS 4825-3 / ASME BPE, DIN 32676 series A
English
24
Install the fitting on the pipe to comply with the
upstream and downstream distances defined by
standard EN ISO 5167-1 (see Fig. 3).
50 x DN 5 x DN
With control valve
25 x DN 5 x DN
Pipe with 2 elbows
at 90°
18 x DN 5 x DN
With pipe expansion
Fig. 3:
Upstream and downstream distances depending
on the design of the pipes.
English
26
/h the dimen-
3
40 x DN 5 x DN
Pipe with 2 elbows at 90°
in 3 dimensions
20 x DN 5 x DN
Pipe with 1 elbow at 90°
or 1 T-piece
15 x DN 5 x DN
With pipe
reduction
gpm
m
/h
3
l/min
1000
200
3000
2000
500
100
1000
50
200
500
100
20
200
50
10
100
5
20
50
10
2
20
5
1
10
0.5
2
5
1
0.2
2
0.5
0.1
1
0.05
0.2
0.5
0.1
0.02
0.2
0.05
0.01
0.1
0.3 0.5
0.3 0.5
1
3
Use a flow conditioner, if necessary, to obtain the best
accuracy.
Prevent the formation of air bubbles in the pipe (see
Fig. 4).
Ensure the pipe is always filled with liquid (see Fig. 5).
Correct
Correct
Direction of fluid flow
Fig. 4:
Additional recommendations on installation
DN65
DN50 (DN65)*
DN40 (DN50)*
DN32 (DN40)*
DN25 (DN32)*
DN20 (DN25)*
DN15 (DN15 or
DN20)*
DN08
DN06
5
m/s
1
3
10
5
10
30
fps
Fluid velocity
English
Incorrect
Incorrect
English
25
25
27
27