3-8. Weld Cable Connections
Rear View
2
−
+
Welding Power
Source
3-9. Input Power Connection
1
8
3
4
5
Tools Needed:
7
Front Panel
Opening
6
1/4 in.
3/4 in.
149920-A / 151113 / 801487-A / Ref. 139439-B
1
2
1
Grommet
2
Positive (+) Weld Output
Terminal On Welding Power
Source
3
Reed Switch
4
Weld Cable (Customer
Supplied)
5
Weld Cable Terminal
6
Weld Power Cable From
Gun/Feeder
7
Weld Power Grommet
Route weld cable and weld power
cable as shown. Be sure lug on
weld cable terminal and lug on
gun/feeder weld power cable make
contact with each other.
8
Contactor W1 (Optional)
Connect weld cable from welding
power source to unused W1
terminal.
Connect weld cable from W1 to
weld cable terminal.
Reinstall wrapper.
1
Grounded Receptacle
A 15 ampere branch circuit
protected by time-delay fuses or
circuit breakers is required.
2
Input Power Cord And Plug
PLG4
Connect input power plug to a
proper receptacle.
Ref. 149548-D