3-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.
3-2. Unit Specifications
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 4-7 and 4-8 for information on con-
necting input power.
Input
Rated
Voltage
Power
Output
Range in
CV Mode
3-Phase
350 A at 34
10−38 V
VDC, 60%
Duty Cycle
*See Section 3-5 for Duty Cycle Rating.
3-3. Dimensions And Weight
Hole Layout Dimensions
A
(298 mm) 11-3/4 in.
B
(42 mm) 1-11/16 in.
C
(400 mm) 15-3/4 in.
D
(485 mm) 19-3/32 in.
E
(221 mm) 8-11/16 in.
F
(39 mm) 1-17/32 in.
G
1/4-20 UNC -2B thread
Weight
(36.3 kg) 80 lb
3-4. Environmental Specifications
A. IP Rating
This equipment is designed for outdoor use. It may be stored, but is not intended to be used
OM-257 486 Page 8
SECTION 3 − SPECIFICATIONS
Amperage
Max.
Range in
Open-
CC Mode
Circuit
Voltage
5−425 A
75 VDC
F
D
C
B
for welding outside during precipitation unless sheltered.
RMS Amps Input at Rated Load Output, 60 Hz
3-Phase at NEMA Load Voltages and Class I
Rating
230 V
380 V
400 V
36.1
22.3
20.6
A
E
G
(318 mm)
12-1/2 in.
804 801-A
IP Rating
IP23
KVA
460 V
17.8
14.2
(610 mm)
24 in.
(432 mm)
IP23 2014−06
KW
13.6
17 in.