Miller FieldPro Remote Kullanıcı El Kitabı - Sayfa 5
Kaynak Aksesuarları Miller FieldPro Remote için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Miller FieldPro Remote 8 sayfaları.
CHECK POLARITY
Indicator
STICK NEGATIVE
Indicator
NOTICE − Controls on the FieldPro Remote are NOT adjustable during welding. To make adjustments during welding, use the power source controls.
Adjustments can be made if using the RHC-14 remote or wireless remote.
Table 6-1. Recommended Process Selections vs Electrode Type
Electrode Type
7.
Routine Maintenance
n = Check
Every
3
Months
l Unreadable Labels
8.
Remote Diagnostics Help Codes
Display Code
H01
H02
H03
Secondary Circuit Over Temperature
H04
Primary Temperature Sensor Malfunction
H05
The CHECK POLARITY text will illuminate along with an error message (Err) if the work and electrode leads are
reversed. This will light only if a FieldPro accessory is connected. Power down and correct the connections (see
Section 4 for proper connections).
The DCEN (−) STICK NEG text will illuminate if the polarity is negative while in STICK mode. To activate DCEN
mode, press the STICK button and down arrow at the same time. Press the STICK button to exit this mode. The
DCEN mode can be used for EXX10 and/or EXX18 process setting. The mode has to be set for each electrode
process individually.
EXXX1
EXXX2
EXXX3
EXXX4
EXXX5
EXXX6
EXXX7
EXXX8
Stainless
~ = Clean
l = Replace
~ Weld Connections
H
Display Example
Fault
Primary Transformer Over Current
Secondary Thermistor Malfunction
Primary Circuit Over Temperature
Suggested Process Setting
!
Disconnect power before maintaining.
n Tighten Weld Connections
0
1
Indicates a malfunction in the primary power circuit. If this code
appears on the display, contact the nearest Factory Authorized
Service Agent.
Indicates the left side thermal protection circuitry is
malfunctioning. If this code appears on the display, contact the
nearest Factory Authorized Service Agent.
Indicates left side of unit has overheated. Unit has shutdown to
allow fans to lower left side temperature. Operation will continue
after unit is within normal temperature range.
Indicates the right side thermal protection circuitry is
malfunctioning. If this code appears on the display, contact the
nearest Factory Authorized Service Agent.
Indicates right side of unit has overheated. Unit has shutdown
to allow fans to lower right side temperature. Operation will
continue after unit is within normal temperature range.
EXX10
EXX10
EXX18
EXX18
EXX18
EXX18
EXX18
EXX18
EXX18
nl Weld Cables And Cords
Description
OM-257 886 Page 5