Miller Subarc DC 1000 Kullanıcı El Kitabı - Sayfa 25
Taşınabilir Jeneratör Miller Subarc DC 1000 için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Miller Subarc DC 1000 48 sayfaları.
3-3. Using Multiple Units: Two or More AC Arcs With Separate Electrodes
Y ELECTRIC SHOCK can kill.
Do not touch live electrical parts.
Turn off welding power sources and disconnect input power before making any weld output con-
nections.
See ANSI Z49.1 and OSHA Title 29, Chapter XVII, Part 1910, Subpart Q (addresses at begin-
ning of manual).
Do not handle or come in contact with two live electrodes at the same time.
Y UNDERSIZED WELD CABLES can cause fire.
Work cable or electrode cable must be able to carry the weld output of the individual welding power
source (see Section 2-8).
Securely cover common connections with proper insulating material as shown in detail below.
Do not exceed duty cycle of welding power sources.
First Unit
Connections
Y High weld output current hazard! Remove all metal jewelry, such as rings
and watches, and be careful with tools near output terminals. High cur-
rent can cause severe burns from hot metal if touched to output terminals
and unit is On. ALWAYS turn Off welding power sources and disconnect
input power BEFORE making weld output connections.
Y If there are any questions regarding
this procedure, contact the factory be-
fore connecting units.
To AC Output
Electrode #1
Second Unit (And
Following Units)
Connections
To Work
Shielded Cable To
Terminal Strip TE4
Y Turn Off welding power
source and disconnect input
power before opening ac-
cess door.
To use two or more ac arcs with
separate electrodes, make con-
nections as shown.
Set up ac output units according to
Section 3-6 or 3-7, as applicable.
Y When using multiple arcs in
parallel, be sure to follow
unit setup instructions care-
fully. Severe damage to units
may occur if units are not
correctly connected for par-
allel operation.
To AC Output
Electrode #2
To Next AC Unit
To Work
ST-801 882-A
OM-2221 Page 21