4-10. Connecting Remote Control

4-11. Electrical Service Guide

A. 1000 Ampere Rated Welding Output
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Min Input Conductor Size In AWG
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG
Reference: 1999 National Electrical Code (NEC)
1 Consult factory for circuit breaker applications.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose - no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.
OM-2223 Page 18
OR
1
A
J
B K
I
C L N
H
D M
G
E F
3
4
1
Time-Delay
Normal Operating
4
4
OR
2
230
180
2
225
3
250
3/0
204
(62)
4
Y Turn off power before con-
necting to receptacle.
1
Remote 14 Receptacle RC8
Connect remote control to RC8. If
plug does not fit, wire cord to
terminal strip 1T.
Y Turn Off power before open-
ing terminal strip cover.
2
Terminal Strip 1T
3
Remote Control Cord
4
Strain Relief (Customer
Supplied)
Secure cord
in
strain relief.
Reinstall and secure access panel.
Close door.
Ref. 802 295 / Ref. S-0004-A / S-0750
60 Hz
460
575
90
72
110
90
125
110
3
4
337 (103)
438 (134)
6
6