6. INSTALLATION

6.1 Controlling the appliance upon receipt

Before unpacking the appliance, check that the outer protective casing is fully intact.
Any damage must be promptly reported to the courier. In any case, no damaged appliance can be returned to the manufacturer without prior notice and
without prior written authorisation.

6.2 Positioning

The described operations must be carried out by qualified personnel. Before performing any installation procedure, disconnect the appliance from
the power mains. Place the appliance in a ventilated room away from heat sources, in order to ensure that there is a sufficient air supply in the area
housing the compressor. The refrigerated unit has been designed for use in a room with a maximum temperature of 43°C. If the room temperature is
higher, this may also have an effect on the temperature of the appliance and may result in it malfunctioning or becoming damaged.
Set down the appliance where desired using a pallet truck. If the unit is moved after it has been unpacked, protect the surfaces from knocks. Once the
installation has been carried out, the protective film can be removed. This operation should be performed very slowly to prevent the glue from remaining
on the surfaces.
The equipment is supplied with adjustable feet to obtain the desired height and compensate for any unevenness or slope of the floor.
WARNING: Do not obstruct the holes made in the units to ventilate the technical compartment; any obstruction could cause the appliance to malfunction.
WARNING: Do not store or use flammable materials and liquids near the appliance, and do not use electrical devices inside the compartments.

6.3 Preparations to be made by the client

Use an earthed socket with an adequate capacity for the absorption indicated on the rating plate.
Before installing the appliance, check the flatness of the floor. Incorrect levelling can cause the appliance to malfunction.

6.4 Electrical connections

They must be carried out in accordance with the local regulations in force. Before performing the electrical connection, make sure that the
voltage and frequency correspond to the information indicated on the appliance's rating plate. The electrical connection is carried out by connecting
the appliance's plug to a socket in the room; this socket must still remain accessible after the installation.
The cable must have the minimum properties of a type H05 RNF cable and an efficient, appropriately-sized earthing conductor based on the total
power of the appliance and any other appliances or accessories connected on the same terminal board (see the rating plate).
If the power cable is damaged, it must be replaced by the customer service or qualified personnel.
The appliance's electrical supply system must be equipped upstream with an appropriately-sized automatic omnipolar circuit breaker that ensures a
gap of at least 3 mm between the contacts. There must not be any breaks in the earth cable.
The electrical safety of this appliance is only guaranteed when the above-mentioned conditions are met and if the system's equipotential
situation is also compliant (use the connection screw located near the power cable input and the symbol sticker).
Any operations carried out on electrical systems must be performed by qualified personnel.
The manufacturer declines all responsibility in the event that these safety standards are not complied with.

7. OPERATION/USE

7.1 Intended use and restrictions

Before using the appliance for the first time, clean the inside with warm water and mild soap. Avoid using abrasive detergents or scouring powders.
Lastly, rinse and dry the appliance thoroughly. The manufacturer declines all responsibility if the products are not used as intended.
The machines have not been designed for use in unsupervised environments. Furthermore, the appliances are not suitable for outdoor installations
and/or environments subjected to the weather (rain, direct sunlight, etc.).
Avoid placing hot food or evaporating liquids inside the appliance, as its function is to preserve the product's temperature, and not to lower it; the
product should therefore only be inserted if it has already cooled down.
Cover or wrap foods to be preserved.
Only keep the doors/drawers open for as long as it takes to insert or remove the food.
The maximum load for each shelf / drawer is indicated in Tab. 1, p. 54.
Do not store explosive substances such as pressurised containers or items containing a flammable propellent.

7.2 Commissioning the appliance

Insert the circuit breaker located upstream from the appliance.
Press the main switch (B) on the control panel (Fig. 1). The built-in indicator light turns on to indicate that the appliance is powered.
Turn on the digital thermoregulator (A), shown in Fig. 1, by holding down button 4 for at least 5 seconds (see the figure of the digital thermostat).
If the temperature in the refrigerated unit is higher than the thermostat-set value, the compressor starts and the digital thermostat's indicator light (6)
comes on.