7. Replacement of modules. See Fig. 6
To replace the modules K5 and K7:
•
Set the input tap on the connection node to the "Closed" position and open the fresh water tap to to relieve the pressure.
•
Press the stop button all the way down and while holding it, turn the filter module counter-clockwise and remove it.
•
Remove the heat shrinkable film from the new module.
•
Wash the module O-rings under running water.
•
Insert the module into the appropriate manifold until all the way in and, gently pushing it, turn the module clockwise till it clicks.
•
Set the input tap on the connection node to the "Open" position and make sure that the water purifier is sealed.
ATTENTION! Replacement and maintenance of the tank with replaceable backfilling should be done by the servicing unit.
Lifetime of the tank with replaceable backfilling depending on the hardness of the water
Hardness, degrees
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
ATTENTION! These figures are relevant for a new tank with replaceable backfill.
8. Rules of storage and transportation
Shelf life of the water purifier before the start of operation is 3 years at a temperature of + 5 to + 35 ° C, in polyethylene packaging and
carton in closed rooms with natural ventilation with relative humidity not exceeding 80%. Do not tilt the water purifier, subject it to
mechanical impacts and other influences.
The water purifier can be transported by all types of covered vehicles.