AQUAPHOR OSMO PRO 50 EU Manuel - Sayfa 8

Su Filtrasyon Sistemleri AQUAPHOR OSMO PRO 50 EU için çevrimiçi göz atın veya pdf Manuel indirin. AQUAPHOR OSMO PRO 50 EU 16 sayfaları.

AQUAPHOR OSMO PRO 50 EU Manuel
Installing the connection node
...........................................................................................
ATTENTION! The end of the pipeline to which
the connection unit is connected must be flat.
Do not use significant force when tightening the
union nut. Failure to do so will damage the gasket.
...........................................................................................
14. Install the connection unit (23) between the
cold water supply and the connecting pipe
(24) as shown in the Water purifier installation
diagram. If necessary, use the seal tape to seal
the external thread of the connection unit.
15. Connect inlet tube (24). See section "Con-
necting tubes".
16. Close the connection unit (position "Tap
closed") and, turning on the water, make sure
that the connections are tight (no leaks).
17. Assemble the water purifier by installing the
cartridges in the housing (see the section
"Installing Cartridges"). The order of installa-
tion of the cartridges is shown in the "Water
purifier installation diagram".
Connecting tubes
Connect the supplied OSMO Pro pipes according
to the "Water purifier installation diagram".
Red tube (24) – from the connection unit (23) to
the inlet (25) of the housing (1).
Black tube (16) – from the housing (1) to drain
clamp (17).
A blue tube with a pressed brass bushing (6) –
from the outlet fitting (5) of the air conditioning
unit (4) to the fresh water tap (7).
The blue tube of the storage tank (22) – from the
housing (1) to the storage tank tap (20).
How to connect tubes
Pull the retaining clip out from under the plastic
sleeve, insert the end of the tube, pre-moistened
with water, into the fitting sleeve until it stops
to a depth of about 15 mm and replace the clip.
...........................................................................................
ATTENTION! Check the tightness of the tube
fastening – with a force of 8–10 kgf, the tube
should not be pulled out.
...........................................................................................
8
How to disconnect tubes
Pull the retaining clip out from under the plastic
sleeve and, by pressing the end of the plastic
sleeve with a wrench (included in the water pu-
rifier kit), pull out the tube.
Installing cartridges
To install the filter cartridge:
• remove the protective film from the cartridge;
• make sure that the inner surfaces of the car-
tridge connection flange are clean (no coal dust,
etc.); rinse the flange under running water if
necessary;
• insert the cartridge into the housing as far as it
will go and, pressing slightly, turn it clockwise
until it clicks.
...........................................................................................
NOTE. There is no need to install the membrane
cartridge at this stage. To flush the filter, screw
the flush plug into the middle slot of the housing.
...........................................................................................